HCL711 Anchoring System ( # 2411 )


larger viewHCL-711  (#2411)
larger viewHCL-711 Anchoring System (#2411)
larger viewHCL-711  (#2411)  Seismic Application
larger view HCL-711  (#2411)  with Pintle (#2402)
larger viewHCL-711  (#2411)

DESCRIPTION
  • HCL-711 Anchoring system installs quickly and easily on exterior walls with brick veneer while providing positive contact with metal stud and avoiding damage to wallboard.
  • The HCL-711 System moves the dew point from within the stud to near the outer face of the rigid insulation, reducing potential corrosion at the screw locations.
  • Especially useful in high wind environments and seismic areas D and E where wallboard is installed between the steel stud and insulation.
  • Simplified installation procedure saves on labor costs.
  • Compatible with the WIRE-BOND® Clip System used in seismic zones.
GAUGES AND FINISHES:
  • HCL711 Plate:14 gauge hot dip galvanized or stainless steel.
  • Pintle: 3/16″ diameter hot dip galvanized or stainless steel.
“LEGS” DESCRIPTION AND SIZES:
  • “LEGS”: 1″, 1-1/2″, 2″, 2-1/2″, and 3″ to accommodate insulation or without extensions.
  • The “legs” of the HCL-711s provide the platform for the insulation. This eliminates potential insulation damage and improves thermal performance. R value is maintained.
  • The installer does not have to penetrate varying amounts of insulation while guessing for direct contact with the stud.
  • The pintles serve to secure the insulation to the exterior wallboard. The simplified installation procedure saves on labor costs.
PRONGS:
  • Three pointed prongs which pierce wallboard and abut to the steel stud.
  • Triangular pattern of the 14 gauge prongs allows little or no compressible movement where the wallboard may deteriorate.
  • Prongs extend through 5/8″ wallboard.
SQUARE GRID:
  • With the metal studs spaced at 16″ intervals, the system provides a 16″ squared grid. This is accomplished with two easy steps:
  • 1. First, 8-foot-wide insulation is installed as a guide from the footer
    of the wall. The 16″ height of the insulation indicates where the next horizontal line of HCL-711s will attach at the vertical line of wallboard fasteners.
  • 2. The insulation is then inlaid snugly between the legs of the uniform
    horizontal lines of HCL-711s.