G E N E R A L  I N F O R M A T I O N                                       WIRE-BOND






                ASTM A1064/A1064M Wire Requirements  ( for cold drawn steel wire )
                QQ-W-461 f Finish 1 Wire Requirements  ( for hard tempered wire )



                Tensile Strength                   80,000 PSI
                Yield Point                        70,000 PSI minimum
                Reduction of Area                  30%



                Wire Gauges                        Side Rods                            Cross Rods


                Standard                           9 Gauge ( .148 in )                   9 Gauge
                Heavy Duty                         3/16” ( .187 in )                     9 Gauge
                Extra Heavy Duty                   3/16” ( .187 in )                     3/16”


                Finishes                                         Description


                Plain                                            Uncoated
                Mill Galvanized                                  Zinc Coated ( 0.10 oz per sq ft )
                Hot Dipped Galvanized After Fabrication          Zinc Coated ASTM A153 / A153M-B2 (1.50 oz per sq ft)
                Stainless Steel                                  ASTM A580 / ASTM A580M Type 304




                All wire conforms to ASTM A951 / A951M-06.  This specification covers the manufacturing guidelines and
                minimum weld strength required for masonry joint reinforcement.

                                                                         2
                TMS 402 Code recommends mill galvanized ASTM A641 ( 0.1 oz/ft   ) for joint reinforcement in interior walls. For
                                                                                   2
                cavity and exterior walls hot dipped galvanized ASTM A153 / A153M-B2 (1.50 oz per sq ft ) ( 485 g/m  ) is
                recommended for joint reinforcement, wire ties, and anchors. Hot dipped or Stainless Steel is also recommended
                for walls exposed to a mean relative humidity exceeding 75%.
                Class I ASTM A641 ( 0.4 oz/ft   ) and Class III ( 0.8 oz/ft  ) are no longer recommended by TMS 402 for interior
                                                                2
                                         2
                walls.
                Epoxy coating is not recommended as a protective coating for joint reinforcement, anchors and ties. Manufacturer
                recommends Stainless Steel Type 304 for maximum corrosion protection.




                WIRE-BOND®’s products are manufactured in compliance with the following building codes:
                                                                   • CSA A370-94 - Connectors for Masonry
                • SBCC - Southern Building Code Congress
                • BOCA - Building Officials Congress in America    • TMS 402 - Building Code Requirements
                • ICBO - International Congress of Building Officials                                  for Masonry Structures




           Visit wirebond.com to see our complete catalog of masonry joint reinforcement
           products and accessories.







           WIRE-BOND       800 - 849 - 6722         For Material Conformance / Submittal Sheets, see wirebond.com  3