Page 9 - fero wirebond catalog
P. 9
LOAD TABLE AND DESIGN INFORMATION
FAST™ MAXIMUM MAXIMUM MAXIMUM ALLOWABLE VENEER HEIGHT
BRACKET ALLOWABLE VERTICAL BRACKET CLAY BRICK LIGHTWEIGHT NORMAL WEIGHT NATURAL
DEPTH "D" LOAD PER BRACKET SPACING CONCRETE BLOCK CONCRETE BLOCK STONE
in. (mm) lb. (kN) ft. (mm) ft. (m) ft. (m) ft. (m) ft. (m)
2 (600) 18.7 (5.6) 25.0 (7.6) 19.7 (6.0) 15.3 (4.6)
1.0 (25) 1500 (6.7) 3 (900) 12.5 (3.8) 16.6 (5.0) 13.1 (3.9) 10.4 (3.1)
4 (1200) 9.3 (2.8) 12.5 (3.8) 9.8 (2.9) 7.7 (2.3)
2 (600) 17.5 (5.3) 23.3 (7.1) 18.4 (5.6) 15.3 (4.6)
1.5 (38) 1400 (6.2) 3 (900) 11.6 (3.5) 15.5 (4.7) 12.2 (3.7) 10.4 (3.1)
4 (1200) 8.7 (2.6) 11.6 (3.5) 9.2 (2.8) 7.7 (2.3)
2 (600) 26.2 (7.9) 35.0 (10.6) 27.6 (8.4) 23.3 (7.1)
2.0 (51) 2100 (9.3) 3 (900) 17.5 (5.3) 23.3 (7.1) 18.4 (5.6) 15.6 (4.7)
4 (1200) 13.1 (3.9) 17.5 (5.3) 13.8 (4.2) 11.6 (3.6)
2 (600) 26.2 (7.9) 35.0 (10.6) 27.6 (8.4) 23.3 (7.1)
2.5 (64) 2100 (9.3) 3 (900) 17.5 (5.3) 23.3 (7.1) 18.4 (5.6) 15.6 (4.7)
4 (1200) 13.1 (3.9) 17.5 (5.3) 13.8 (4.2) 11.6 (3.6)
2 (600) 26.2 (7.9) 35.0 (10.6) 27.6 (8.4) 23.3 (7.1)
3.0 (76) 2100 (9.3) 3 (900) 17.5 (5.3) 23.3 (7.1) 18.4 (5.6) 15.6 (4.7)
4 (1200) 13.1 (3.9) 17.5 (5.3) 13.8 (4.2) 11.6 (3.6)
2 (600) 26.2 (7.9) 35.0 (10.6) 27.6 (8.4) 23.3 (7.1)
3.5 (89) 2100 (9.3) 3 (900) 17.5 (5.3) 23.3 (7.1) 18.4 (5.6) 15.6 (4.7)
4 (1200) 13.1 (3.9) 17.5 (5.3) 13.8 (4.2) 11.6 (3.6)
2 (600) 24 (7.3) 32.0 (9.7) 25.3 (7.7) 21.4 (6.5)
4.0 (102) 1925 (8.6) 3 (900) 16 (4.8) 21.3 (6.4) 16..8 (5.1) 14.3 (4.4)
4 (1200) 12 (3.6) 16.0 (4.8) 12.6 (3.8) 10.6 (3.2)
2 (600) 21.8 (6.6) 29.1 (8.8) 23.0 (7.0) 19.4 (5.9)
4.5 (114) 1750 (7.8) 3 (900) 14.5 (4.4) 19.4 (5.9) 15.3 (4.6) 13.0 (4.0)
4 (1200) 10.9 (3.3) 14.5 (4.4) 11.5 (3.5) 9.7 (2.9)
2 (600) 19.6 (5.9) 26.2 (7.9) 20.7 (6.3) 17.5 (5.3)
5.0 (127) 1575 (7.0) 3 (900) 13.1 (3.9) 17.5 (5.3) 13.8 (4.2) 11.7 (3.6)
4 (1200) 9.8 (2.9) 13.1 (3.9) 10.3 (3.1) 8.7 (2.7)
2 (600) 17.5 (5.3) 23.3 (7.1) 18.4 (5.6) 15.5 (4.7)
5.5 (140) 1400 (6.2) 3 (900) 11.6 (3.5) 15.5 (4.7) 12.2 (3.7) 10.4 (3.2)
4 (1200) 8.7 (2.6) 11.6 (3.5) 9.2 (2.8) 7.7 (2.4)
2 (600) 15.6 (4.7) 20.8 (6.3) 16.4 (4.9) 13.9 (4.2)
6.0 (152) 1250 (5.6) 3 (900) 10.4 (3.1) 13.8 (4.2) 10.9 (3.3) 9.3 (2.8)
4 (1200) 7.8 (2.3) 10.4 (3.1) 8.2 (2.4) 6.9 (2.1)
2 (600) 13.7 (4.1) 18.3 (5.5) 14.4 (4.3) 12.2 (3.7)
6.5 (165) 1100 (4.9) 3 (900) 9.1 (2.7) 12.2 (3.7) 9.6 (2.9) 8.2 (2.5)
4 (1200) 6.8 (2) 9.1 (2.7) 7.2 (2.1) 6.1 (1.9)
2 (600) 12.7 (3.8) 17.0 (5.1) 13.4 (4.0) 11.3 (3.4)
7.0 (178) 1020 (4.5) 3 (900) 8.5 (2.5) 11.3 (3.4) 8.9 (2.7) 7.5 (2.2)
4 (1200) 6.3 (1.9) 8.5 (2.5) 6.7 (2.0) 5.6 (1.7)
FAST Thermal
Bracket Depth "D"
FERO 9
FERO FAST™ Bracket
United States Patent US 6,128,883
Canadian Patents CA 2,284,069; CA 2,254,510; CA 2,591,687;
CA 2,759,747; CA 2,759,837; and CA 2,759,778
Other Patents Pending
Drawn by:
Engineering 2018-12-19 ENGINEERED MASONRY CONNECTORS
FERO D
Checked by: 15305-117 Avenue NW,ENDOMONTON AB, CANADA T5M-3X4
Tel: (780) 455-5098 Fax: (780) 452-5969
www.ferocorp.com E-mail: info@ferocorp.com
Title:
Manufacturing approval by:
TM
Approved by: FERO FAST System
Size: Dwg no: Rev:
C Assembly2
Material:
Mass: Scale: Sheet:
N/A Autodesk inventor file 1 Of 1
3 4